Smoke Testing, CCTV & Jetting: How Indiana Municipalities Find and Fix Inflow and Infiltration

Hydromax Services performing inflow and infiltration detection with smoke testing and CCTV for an Indiana municipality.

For Indiana municipalities and utilities, inflow and infiltration is a year-round concern. When excess groundwater and stormwater sneak into sanitary sewer systems, the results can be overwhelmed treatment plants, sanitary sewer overflows, and costly emergency repairs.

The smart move is to find those weak points before they turn into emergencies. At Hydromax Services, we help municipal and commercial clients across the region locate inflow and infiltration using three proven techniques: smoke testing, CCTV video inspection, and high-pressure jetting. Here’s how each works, and how municipalities put the results to use.

First: What Is Inflow and Infiltration (I&I)?

Inflow and infiltration, or “I&I,” refers to unwanted water entering a sanitary sewer system that was never meant to carry it.

  • Infiltration is groundwater seeping in through cracks, defective pipe joints, and deteriorated lines.
  • Inflow is stormwater entering more directly, through improper connections like downspouts, sump pumps, or manhole covers.

Why does it matter so much? As the U.S. Environmental Protection Agency explains, excessive infiltration and inflow is a leading cause of sanitary sewer overflows, releases of untreated sewage that threaten public health and the environment. Reducing I&I protects both the system and the community.

Learn more about sanitary sewer overflows from the EPA here.

Why Proactive I&I Detection Matters

I&I problems are at their worst when the ground is saturated and stormwater is heavy. By identifying and addressing weak points before peak-flow conditions arrive, municipalities can:

  • Reduce the risk of sanitary sewer overflows
  • Avoid emergency response costs during high-flow events
  • Prioritize repairs strategically instead of reactively
  • Ease the load on treatment facilities before demand spikes

Proactive I&I detection is one of the most cost-effective investments a utility can make. Here are the three tools we use to pinpoint the problem.

Tool #1: Smoke Testing

Smoke testing is a fast, effective way to reveal defects and improper connections across a large area of the sewer system. The process involves blowing non-toxic smoke into a sewer line; the smoke escapes anywhere there’s a leak, crack, or unauthorized connection.

Where the smoke surfaces, from the ground, a downspout, a foundation, or a faulty joint, you’ve found a point where inflow and infiltration can enter. It’s an efficient way to survey many potential problem areas quickly.

Learn about our smoke testing service here.

Tool #2: CCTV Video Camera Inspection

When you need to see exactly what’s happening inside a pipe, there’s no substitute for CCTV inspection. We send a high-resolution camera through the sewer line to visually document its condition from the inside out.

This lets us pinpoint:

  • Cracks and fractures
  • Root intrusion
  • Deteriorated or offset joints
  • Pipe collapses and blockages
  • Exact locations and depths of defects

The result is a precise, recorded diagnosis, so repairs can be targeted exactly where they’re needed, rather than guessing.

Learn about our video camera inspection service here.

Tool #3: High-Pressure Water Jetting

Jetting plays a crucial supporting role in I&I work. High-pressure water jetting uses powerful streams of water to clear grease, sediment, roots, and debris from sewer lines, and that cleaning is what makes an accurate inspection possible.

A line full of buildup can’t be properly evaluated; a camera can’t see cracks or defective joints through grease and sediment. By thoroughly cleaning the line first, jetting prepares the pipe so CCTV inspection can capture a clear, complete picture of its true condition. It also removes the buildup that contributes to blockages and backups during high-flow events.

In other words, jetting doesn’t identify I&I on its own, it clears the way so smoke testing and CCTV inspection can do their job accurately.

Learn about our water jetting service here.

Turning Inspection Results Into a Repair Plan

Finding the problems is only half the value, the real payoff is in what municipalities do with the findings. Once smoke testing and CCTV inspection are complete, the results give decision-makers a clear, documented roadmap:

  • Pinpoint and prioritize. Recorded video and defect locations let utilities rank problems by severity, tackling active overflow sources and major structural defects first.
  • Match the repair to the defect. Detailed findings help determine the right fix for each issue, from trenchless rehabilitation of a cracked line to correcting an improper connection flagged during smoke testing.
  • Budget and plan with confidence. A documented condition assessment supports capital planning, grant applications, and regulatory reporting, so spending is directed where it delivers the most impact.
  • Track the system over time. Baseline inspection records make it easy to monitor how the system changes and verify that completed repairs are performing as intended.

The result is a data-driven maintenance strategy, repairs made where they matter most, instead of reacting to the next overflow.

A Complete I&I Partner for Indiana Municipalities

Finding inflow and infiltration is only the beginning, the real value is having one experienced partner who can detect and fix the problem. Beyond detection, Hydromax offers trenchless rehabilitation, stormwater management, and the full range of underground infrastructure services municipalities rely on.

See how we support municipal clients here.

Explore our stormwater management services here.

Schedule Your I&I Assessment

Don’t wait for the next heavy rain to expose your system’s weak points. With 45+ years of experience serving municipal, commercial, and industrial clients, Hydromax Services has the tools and expertise to help you find and fix I&I before it becomes an emergency.

Contact our team to plan your assessment.

Frequently Asked Questions

I&I is unwanted water entering a sanitary sewer system. Infiltration is groundwater seeping in through cracks and defective joints; inflow is stormwater entering through improper connections like downspouts or manholes. Excess I&I can overwhelm the system and cause overflows.

The findings from smoke testing and CCTV inspection let utilities prioritize repairs by severity, choose the right fix for each defect, support budgeting and grant applications, and track system condition over time, turning inspection data into a strategic repair plan.

Smoke testing quickly surveys a large area to reveal leaks and improper connections where smoke escapes. CCTV inspection sends a camera inside the pipe for a precise, recorded view of its condition. Jetting cleans the line beforehand so the inspection is accurate, it prepares the pipe rather than identifying I&I directly.

Yes. Hydromax Services works with municipal, commercial, and industrial clients, offering I&I detection, trenchless rehabilitation, stormwater management, and full underground infrastructure services, backed by 45+ years of experience.

The information provided in this blog is for general informational purposes only and does not constitute professional plumbing advice. Always consult with a licensed professional or your service provider for guidance specific to your property or project needs. Hydromax Services is not liable for any errors, omissions, or outcomes resulting from the use of this information. For project-specific recommendations, please contact our team directly.

Recent Blogs

Section 1 — About Your Organization

Registered 501(c)3 Nonprofit?

Section 2 — About Your Request

Type of Request

Section 3 — Recognition & Benefits

Section 4 — Additional Information

Previous support from Hydromax or AGS Hauling?
Clear Signature